Flange size and rating chart
Outside diameter, bolt circle and bolting for the flange sizes most used on immersion and pipeline heaters. Tell us the standard and class of your nozzle and we match it.
ASME B16.5 Class 150
| NPS | Outside dia. | Bolt circle | Bolts |
|---|---|---|---|
| ½" | 88.9 mm3.50 in | 60.5 mm2.38 in | 4 × ½" |
| ¾" | 98.6 mm3.88 in | 69.8 mm2.75 in | 4 × ½" |
| 1" | 107.9 mm4.25 in | 79.2 mm3.12 in | 4 × ½" |
| 1¼" | 117.3 mm4.62 in | 88.9 mm3.50 in | 4 × ½" |
| 1½" | 127.0 mm5.00 in | 98.6 mm3.88 in | 4 × ½" |
| 2" | 152.4 mm6.00 in | 120.6 mm4.75 in | 4 × ⅝" |
| 2½" | 177.8 mm7.00 in | 139.7 mm5.50 in | 4 × ⅝" |
| 3" | 190.5 mm7.50 in | 152.4 mm6.00 in | 4 × ⅝" |
| 4" | 228.6 mm9.00 in | 190.5 mm7.50 in | 8 × ⅝" |
| 5" | 254.0 mm10.00 in | 215.9 mm8.50 in | 8 × ¾" |
| 6" | 279.4 mm11.00 in | 241.3 mm9.50 in | 8 × ¾" |
| 8" | 342.9 mm13.50 in | 298.4 mm11.75 in | 8 × ¾" |
| 10" | 406.4 mm16.00 in | 361.9 mm14.25 in | 12 × ⅞" |
| 12" | 482.6 mm19.00 in | 431.8 mm17.00 in | 12 × ⅞" |
EN 1092-1 PN16
| DN | Outside dia. | Bolt circle | Bolts |
|---|---|---|---|
| DN 15 | 95 mm | 65 mm | 4 × M12 |
| DN 20 | 105 mm | 75 mm | 4 × M12 |
| DN 25 | 115 mm | 85 mm | 4 × M12 |
| DN 32 | 140 mm | 100 mm | 4 × M16 |
| DN 40 | 150 mm | 110 mm | 4 × M16 |
| DN 50 | 165 mm | 125 mm | 4 × M16 |
| DN 65 | 185 mm | 145 mm | 8 × M16 |
| DN 80 | 200 mm | 160 mm | 8 × M16 |
| DN 100 | 220 mm | 180 mm | 8 × M16 |
| DN 125 | 250 mm | 210 mm | 8 × M16 |
| DN 150 | 285 mm | 240 mm | 8 × M20 |
| DN 200 | 340 mm | 295 mm | 12 × M20 |
| DN 250 | 405 mm | 355 mm | 12 × M24 |
| DN 300 | 460 mm | 410 mm | 12 × M24 |
How it is worked out
Values are taken from ASME B16.5 and EN 1092-1. Raised-face height, flange thickness and hub dimensions depend on the flange type (weld neck, slip-on, blind) and are confirmed on the general-arrangement drawing.
JIS B2220 and other standards are built to order; state the standard, class and face type in your inquiry.
Other selection tools
- Heater sizing calculator Required kW for continuous flow or batch heat-up of water, thermal oil or air.
- Watt density guide Design ranges by medium, and why oil needs a larger heater than water for the same kW.
- Electric vs gas operating cost Annual energy cost of the same heat duty from an electric heater and a gas-fired heater.
- Thermal oil properties Density, specific heat and conductivity of a typical mineral heat transfer oil by temperature.
- Unit converter Power, temperature, pressure, flow and watt density units used on heater datasheets.
For a quotation, include your process medium, operating temperatures and supply voltage.